Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Assoc Off Anal Chem ; 69(6): 935-8, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3804945

RESUMO

Residue depletion studies were conducted in dairy cattle to monitor morantel-related residues in milk following oral administration of morantel tartrate (Rumate. Eleven lactating cows of various ages, periods of lactation, and known milk production were orally dosed with the bolus formulation of morantel tartrate with an actual dose range of 8.4-9.8 mg/kg body weight. Representative samples of milk were collected at 10-14 h intervals post-dose, and subsamples were assayed for the major and minor hydrolysis products of morantel-related residues, MAPA and CP-20,107. Residues assayed as precursors of MAPA peaked at the second milking (24 h post-dose) and were below 25 ppb (range: less than 12-24 ppb). Precursors of CP-20,107, which confirm the identity of morantel, also peaked at 24 h post-dose (range: 2.1-3.3 ppb) and declined rapidly thereafter. A statistical model was used to project the level of residues at the upper limit of 99% of the total target animal (i.e., dairy cattle) population with 95% confidence. The calculated peak levels from this model were 50 and 5.0 ppb for morantel-related residues convertible to MAPA and CP-20,107, respectively.


Assuntos
Leite/análise , Morantel/análise , Pirimidinas/análise , Animais , Bovinos , Feminino , Cinética , Morantel/análogos & derivados
2.
J Assoc Off Anal Chem ; 69(4): 646-51, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3745093

RESUMO

A gas chromatographic assay was developed to determine major residues of morantel in bovine milk over a range that is suitable for monitoring residues of the drug. The method is based on hydrolysis of the N-methyl-tetrahydropyrimidine portion of morantel and its metabolites to N-methyl-1,3-propanediamine, and converting the diamine to an N,N-bis-(2-nitro-4-trifluoromethylphenyl) derivative. The addition of an internal standard, the N-desmethyl-N-ethyl homolog of pyrantel, to the milk sample circumvents any potential problem that could arise from variable reaction yields, and eliminates the true recovery as a factor affecting the accuracy and precision of the procedure. The concentrations of the derivatives are determined by pulsed electron capture gas chromatography over a linear dynamic range that is equivalent to 12.5-50 ppb morantel. The method was evaluated at the 0, 12.5, 25, and 50 ppb levels in fortified bovine milk, and in a withdrawal sample containing physiologically incurred morantel residues. Mean values of 14 +/- 1.7, 24 +/- 3.7, and 47 +/- 6.9 were found for the fortified samples, approximately 3 ppb for control milk, and 16 +/- 1.7 ppb for the withdrawal sample.


Assuntos
Leite/análise , Morantel/análise , Pirimidinas/análise , Animais , Bovinos , Fenômenos Químicos , Química , Cromatografia Gasosa , Cromatografia em Camada Fina , Hidrólise , Indicadores e Reagentes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...